Microprocessor Solution Analyzer Kit




Features:

  • Easy to handle
  • Low maintenance
  • Rugged casing

Specifications

Model No. SI-158
Performance Optimum
Speciality Rust resistance
Condition New
Features Long functional life
Efficiency Consistent


Technical Data

pH
  • Range: 0-14 pH
  • Resolution: 0.01pH
  • Accuracy : + 0.01 pH ( relative)
  • Temp. Comp. : Automatic with Pt100 Sensor &Manual by keys
  • Buffer Recognition : 4.00 , 7.00 , 9.20 ( Automatic)
  • Calibration
  • Automatic & Manual
  • 2 Point, 3 Point(Prog.)
Dissolved Oxygen
  • Range : 0 to 20 ppm
  • Resolution : 0. 1 ppm
  • Calibration : Automatic
  • Accuracy : + 0.2 ppm + 1digit
  • Temp. Comp.: Automatic with Pt100 Sensor & Manual By keys
  • Pressure comp : 0-999 mm of Hg ( Manual)
  • Salinity Correction : 0-20 mg/l
mv/ORP
  • Range: 1999 to +1999 mV
  • Resolution: 1 mV
  • Calibration: Manual
  • Accuracy : + 0.1% + 1digit

Temperature

  • Range: 200 to +200 degree C
  • Resolution : 0.1 degree C
  • Accuracy : + 0.2% + 1digit
  • Input : Pt100
  • Calibration : Manual
Conductivity
  • Range : 0-1000 mS/cm
  • Range Selection : Automatic
  • Resolution : 0.01 uS/cm
  • Accuracy: + 0.5%
  • Temp. Comp. : Automatic with Pt100 Sensor
  • Ref. Temp. : 25 degree C/20 degree C(Prog.)
  • Temp. Co-efficient : 0-4% adjustable
  • Cell constant : 0.05 to 2.0 adjustable
TDS
  • Range : 0-1000 ppt
  • Range Selection : Automatic
  • Resolution : 0.1 ppm
  • Accuracy : + 0.5%
  • TDS factor: 0.5 by default( adjustable)
Salinity
  • Range : 0-50 ppt
  • Resolution: 0.1 ppt
  • Temp. Comp : Automatic
  • Accuracy : + 0.5%
  • Salinity factor : 0.75 by default( adjustable)
General
  • Display : 16 characters X 2 lines alpha Numeric BL LCD
  • Display format : Temp. and parameter Simultaneously
  • Real Time Display: 24 Hour Mode With Date & Time
  • Controls : By soft keys Menu Driven
  • Storage: up to 1000 samples
  • Power supply: 230 V +10 % 50 Hz OR 12 V battery
  • Digital Output : Serial RS-232 Parallel Centronics
  • Print format : All Data
  • Date Wise (Programmable) Error Indication : pH Error,ORP Error,T-Error
Option
RS232 & Parallel output available for interfacing to computer/printer
Accessories
  • pH electrode
  • Buffer solutions
  • Conductivity/TDS/Salinity Cell
  • Temp. probe
  • DO probe, DO membranes, KCL
  • Operation manual
  • ORP Electrode AT EXTRA COST

 

Appearance and specifications subject to change due to continuous development

 

Date Tiime Temp (DegC) Parameter MOde SP.No
39794 0.4708333333 T= 020.0 pH= 07.00 Manual 1
39794 0.4708333333 T= 020.0 mV= 0000 Manual 2
39794 0.4708333333 T= 020.0 DO=00.0 ppm Manual 3
39794 0.4715277778 T= 020.0 C=00.00us/cm Manual 4
39794 0.4715277778 T= 020.0 TDS=00.00ppm Manual 5
39794 0.4715277778 T= 020.0 SAL=000.5ppt Manual 6