Microprocessor Solution Analyzer Kit


Microprocessor Solution Analyzer Kit

We have installed all the requisite amenities, necessary for making safe side deliveries. We keep an eye on every aspect and packaging of products is one of them. Staffed with professional packaging employees having experience in this domain; they use premium packing material to ensure zero damage during transportation.

 

Features :

  • Easy to handle
  • Low maintenance
  • Rugged casing.


Technical Specifications

pH
Range: 0-14 pH
Resolution: 0.01pH
Accuracy : + 0.01 pH ( relative)
Temp. Comp. : Automatic with Pt100 Sensor &Manual by keys
Buffer Recognition : 4.00 , 7.00 , 9.20 ( Automatic)
Calibration
Automatic & Manual
2 Point, 3 Point(Prog.)
Dissolved Oxygen
Range : 0 to 20 ppm
Resolution : 0. 1 ppm
Calibration : Automatic
Accuracy : + 0.2 ppm + 1digit
Temp. Comp.: Automatic with Pt100 Sensor & Manual By keys
Pressure comp : 0-999 mm of Hg ( Manual)
Salinity Correction : 0-20 mg/l
mv/ORP
Range: 1999 to +1999 mV
Resolution: 1 mV
Calibration: Manual
Accuracy : + 0.1% + 1digit
Temperature
Range: 200 to +200 degree C
Resolution : 0.1 degree C
Accuracy : + 0.2% + 1digit
Input : Pt100
Calibration : Manual
Conductivity
Range : 0-1000 mS/cm
Range Selection : Automatic
Resolution : 0.01 uS/cm
Accuracy: + 0.5%
Temp. Comp. : Automatic with Pt100 Sensor
Ref. Temp. : 25 degree C/20 degree C(Prog.)
Temp. Co-efficient : 0-4% adjustable
Cell constant : 0.05 to 2.0 adjustable
TDS
Range : 0-1000 ppt
Range Selection : Automatic
Resolution : 0.1 ppm
Accuracy : + 0.5%
TDS factor: 0.5 by default( adjustable)
Salinity
Range : 0-50 ppt
Resolution: 0.1 ppt
Temp. Comp : Automatic
Accuracy : + 0.5%
Salinity factor : 0.75 by default( adjustable)
General
Display : 16 characters X 2 lines alpha Numeric BL LCD
Display format : Temp. and parameter Simultaneously
Real Time Display: 24 Hour Mode With Date & Time
Controls : By soft keys Menu Driven
Storage: up to 1000 samples
Power supply: 230 V +10 % 50 Hz OR 12 V battery
Digital Output : Serial RS-232 Parallel Centronics
Print format : All Data
Date Wise (Programmable) Error Indication : pH Error,ORP Error,T-Error
Option
RS232 & Parallel output available for interfacing to computer/printer
Accessories
pH electrode
Buffer solutions
Conductivity/TDS/Salinity Cell
Temp. probe
DO probe, DO membranes, KCL
Operation manual
ORP Electrode AT EXTRA COST

 

Appearance and specifications subject to change due to continuous development.

 

Date Time Temp(DegC) Parameter Mode SP. No.
39794 0.47 T= 020.0 pH= 07.00 Manul 1
39794 0.47 T= 020.0 mV= 0000 Manul 2
12/12/08 0.47 T= 020.0 DO=00.0 ppm Manul 3
12/12/08 0.47 T= 020.0 C=00.00us/cm Manul 4
12/12/08 0.47 T= 020.0 TDS=00.00ppm Manul 5
12/12/08 0.47 T= 020.0 SAL=000.5ppt Manul 6